HABO TEST

Detailed product description

Features:

Loop Resistance; Frequency; Contact Voltage; Tripping Current Etc.

Color:

Dark red

Materials:

ABS+PC

Size:

180*140*65mm

Weight:

950 gr

Energy:

6*LR14 batteries

digital resistance meter

Product features

1. Comply with IEC/EN 61010-1 1000V CAT II, ​​600V CAT III Safety standards
2. Maximum common mode voltage: 600V AC RMS

3. Display method: it is displayed on the LCD with a maximum value of 6000
4. Measuring range selection: Auto/manual measuring range
5. Frequency detection: Auto
6. Overrange indication:”>”
7. Power consumption: 100mW
8. Storage temperature: -20~70C
9. Working temperature: 0~40C
10. Temperature factor: When the temperature is lower than 18C or above 28C the factor is per(°) x 0.05 x (appointed accuracy)
11. Electromagnetic compatibility: in a 3V/M RF (Radio Frequency) magnetic field, accuracy = appointed accuracy; otherwise, the accuracy is not appointed.
12. Storage elevation: 12000m
13. Usage elevation: 2000m CAT III 600V; 3000 CAT II 600V
14. Size: 200*155*76mm
15. Net Weight: about 500g

Trip-out time
X1 iδν300(slow 500ms); x5 iδν40ms(slow 150ms) ±3ms
Trip-out current
(0.2~1.1)iδν ±0.1 IΔΝ
Contact voltage
0~99.9v ±(10%+0.2V)
Alternating voltage (ui-n,ul-l,ul-e)
0~440v ±(3%+3V)
Frequency
Dc,45~65hz ±1Hz
Loop resistance
0~19.9v ±(10%+0.2V)
(rl)
10.0~99.9v ±(10%+0.2V)
Rl current test
0.5iδν ±(10%+10d)
Multiplying power of test current x0.5,x1,x5
Current level (iδν) 10mA,30mA,100mA; 300mA,500mA
Trigger phase angle 0°or 180°